Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
1.
Braz. dent. j ; 32(5): 67-76, Sept.-Oct. 2021. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1350288

ABSTRACT

Abstract This study evaluated the vertical misfit, passivity, and stress distribution after tightening the screws of different prosthesis. Two implants were used to simulate the rehabilitation of partially edentulous mandible space from the second premolar to the second molar. 40 three-element screw-retained fixed dental prosthesis with distal cantilever were fabricated and divided into four groups according to the method of production of framework (n = 10): G1 = conventional casting one-piece framework, G2 = conventional casting sectioned and laser welding, G3 = conventional casting sectioned and tungsten inert gas (TIG) welding and G4 = framework obtained by CAD/CAM (computer-aided design/computer-aided manufacturing) system. The vertical misfits (both screws tightened) and the passive fit (one screw tightened) were measured under a comparator optical microscope. The data was submitted to Shapiro-Wilk test to enable comparison with ANOVA followed by Tukey with Bonferroni adjust (α = .05). The qualitative analysis of the stress distribution was performed by the photoelastic method. The vertical misfit (both screws tightened) of the G2 (24 μm) and G3 (27 μm) were significantly higher than G4 (10 μm) (p = 0,006). The passive fit (for the non-tightened) of the G1(64 μm) and G3 (61 μm) were significantly higher than the G4 (32 μm) (p=0,009). G1 showed high stress between the implants in the photoelastic analysis and G4 presented lower stress. In conclusion, CAD/CAM method results in less vertical misfit, more passivity, and consequently better stress distribution to the bone.


Resumo Neste estudo foi avaliado desajuste vertical, a passividade e a distribuição de tensões após o aperto dos parafusos de diferentes próteses. Dois implantes foram usados ​​para simular a reabilitação do espaço edêntulo da mandíbula do segundo pré-molar ao segundo molar. Quarenta próteses dentárias fixas parafusadas de três elementos com cantilever distal foram confeccionadas e separadas em quatro grupos de acordo com o método de obtenção da infraestrutura (n = 10): G1 = fundição convencional estrutura monobloco, G2 = fundição convencional seccionada e soldagem a laser, G3 = fundição convencional seccionada e soldagem com gás inerte de tungstênio (TIG) e G4 = infraestrutura obtida pelo sistema CAD / CAM (computer-aided design/computer-aided manufacturing). Os desajustes verticais com ambos os parafusos apertados e os desajustes relativos à avaliação de passividade com um parafuso apertado foram medidos com microscópio comparador óptico. Os dados foram submetidos ao teste de Shapiro-Wilk para comparação com ANOVA seguida de ajuste de Tukey com Bonferroni (α = 0,05). A análise qualitativa da distribuição de tensões foi realizada pelo método fotoelástico. G2 (24 μm) e G3 (27 μm) apresentaram valores significativamente maiores que G4 (10 μm) (p = 0,006) de desajuste vertical (ambos os parafusos apertados). Os valores de desajustes nos G1 (64 μm) e G3 (61 μm), do lado não apertado, foram significativamente maiores que no G4 (32 μm) (p = 0,009). G1 apresentou maior tensão entre os implantes na análise fotoelástica e G4 apresentou menor tensão. O método CAD/CAM resultou em menor desajuste, maior passividade e melhor distribuição de tensões no osso.

2.
Braz. dent. j ; 26(6): 637-641, Nov.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-769571

ABSTRACT

This research evaluated the influence of temporary cements (eugenol-containing [EC] or eugenol-free [EF]) on the tensile strength of Ni-Cr copings fixed with self-adhesive resin cement to the metal coronal substrate. Thirty-six temporary crowns were divided into 4 groups (n=9) according to the temporary cements: Provy, Dentsply (eugenol-containing), Temp Cem, Vigodent (eugenol-containing), RelyX Temp NE, 3M ESPE (eugenol-free) and Temp Bond NE, Kerr Corp (eugenol-free). After 24 h of temporary cementation, tensile strength tests were performed in a universal testing machine at a crosshead speed of 0.5 mm/min and 1 kN (100 kgf) load cell. Afterwards, the cast metal cores were cleaned by scraping with curettes and air jet. Thirty-six Ni-Cr copings were cemented to the cast metal cores with self-adhesive resin cement (RelyX U200, 3M ESPE). Tensile strength tests were performed again. In the temporary cementation, Temp Bond NE (12.91±2.54) and Temp Cem (12.22±2.96) presented the highest values of tensile strength and were statistically similar to each other (p>0.05). Statistically significant difference (p<0.05) was observed only between Provy (164.44±31.23) and Temp Bond NE (88.48±21.83) after cementation of Ni-Cr copings with self-adhesive resin cement. In addition, Temp Cem (120.68±48.27) and RelyX Temp NE (103.04±26.09) showed intermediate tensile strength values. In conclusion, the Provy eugenol-containing temporary cement was associated with the highest bond strength among the resin cements when Ni-Cr copings were cemented to cast metal cores. However, the eugenol cannot be considered a determining factor in increased bond strength, since the other tested cements (1 eugenol-containing and 2 eugenol-free) were similar.


Resumo Esta pesquisa avaliou a influência dos cimentos temporários (contendo eugenol [CE]ou livre de eugenol[LE]) na resistência à tração de copingsde Ni-Cr fixados com cimento resinoso auto-adesivo sobre substrato coronário metálico. Trinta e seis coroas provisórias foram divididas em 4 grupos (n=9) de acordo com os cimentos temporários: Provy, Dentsply (contendo eugenol), Temp Cem, Vigodent (contendo eugenol), RelyXTemp NE, 3M ESPE (livre de eugenol) andTemp Bond NE, KerrCorp (livre de eugenol). Após 24 h da cimentação temporária, testes de resistência à tração foram realizados em uma máquina universal de ensaios, com velocidade de 0,5 mm/min. e célula de carga de 1kN (100 kgf). Em seguida, os núcleos metálicos fundidos foram limpos por meio de raspagem com cureta ejatos de ar. Trinta e seis copings de Ni-Cr foram cimentados sobre os núcleos metálicos com cimento resinoso auto-adesivo (RelyX U200, 3M ESPE). Testes de resistência à tração foram novamente realizados. Na cimentação provisória, Temp Bond NE (12,91±2,54) e Temp Cem (12,22±2,96) apresentaram os maiores valores de resistência à tração e foram estatisticamente semelhantes entre si (p>0,05). Diferença estatisticamente significante (p<0.05) foi observada apenas entre Provy (164,44±31,23) e Temp Bond NE (88,48±21,83)após cimentação dos copingsdeNi-Cr com cimento resinoso auto-adesivo. Além disso, Temp Cem (120,68±48,27) e RelyX Temp NE (103,04±26,09) mostraram valores intermediários de resistência à tração. Em conclusão, o cimento temporário contendo eugenol, Proxy, foi associado com a mais alta resistência de união do cimento resinoso, quando os copingsde Ni-Cr foram cimentados sobre os núcleos metálicos fundidos. Entretanto, o eugenol não pode ser considerado como um fator determinante no aumento da resistência de união, já que outros cimentos testados (1 contendo eugenol e 2 livres de eugenol) foram semelhantes.


Subject(s)
Dental Cements , Metals/chemistry , Chromium Alloys
3.
In. Carreiro, Adriana da Fonte Porto; Batista, André Ulisses Dantas. Prótese parcial removível contemporânea. São Paulo, Santos, 2013. p.249-265, ilus. (BR).
Monography in Portuguese | LILACS, BBO | ID: lil-708395
4.
J. appl. oral sci ; 21(5): 397-402, Sep-Oct/2013. tab, graf
Article in English | LILACS, BBO | ID: lil-690092

ABSTRACT

OBJECTIVE: This study aimed to evaluate the importance of a distal proximal contact on the load transfer to the posterior region of the mandible by non-splinted adjacent implant-supported crowns using photoelastic stress analysis. MATERIAL AND METHODS: A rectangular model (68x30x15 mm) was made of polymethylmethacrylate resin to simulate half of the mandibular arch. One model was completed with resin replicas representing the first premolar and second molar and with two 3.75 mm dia.x11 mm internal hexagon threaded implants replacing the second premolar and first molar. The other model was manufactured in the same way but without the second molar. Both models were duplicated using photoelastic resin. The roots of the teeth replicas were covered with a layer of polyether impression material to simulate the periodontal ligament. Two different vertical loads were applied to the crowns as follows: 1 - single static point load alternately applied to the crowns replacing the second premolar and first molar (50 N); 2 - simultaneous static point loads applied to both of the crowns replacing the second premolar and first molar (100 N). The resulting isochromatic fringe pattern in the photoelastic model was monitored and photographed. RESULTS: All loading conditions studied showed that the presence of the second molar has changed the load transmission and the pattern of stresses. CONCLUSION: Results showed that the presence of a second molar proximal contact can help minimize the stresses around the implants. .


Subject(s)
Humans , Crowns , Dental Implants , Dental Prosthesis, Implant-Supported , Mandible , Biomechanical Phenomena , Bite Force , Models, Dental , Dental Occlusion , Dental Stress Analysis , Elasticity , Molar , Stress, Mechanical
5.
RGO (Porto Alegre) ; 60(4): 455-460, out.-dez. 2012. graf, ilus
Article in English | LILACS, BBO | ID: biblio-874827

ABSTRACT

Objective: To evaluate the effect of brushing, using toothpastes with different fluoride concentrations, on the surface of commercially pure titanium (cp Ti). Methods: Discs (13x4mm) made of cp Ti, embedded in PVC rings and metallographically polished have their surface roughness measured. Tooth brushing simulations (50,400 cycles) were performed: speed of 80mm/s, distance of 10mm distance, at 240 cycles/min. Three toothpastes were tested: Prevident 5000 (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brazil), Colgate Total 12 (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brazil) and Tandy (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brazil), with 5000, 1300 and 500ppm fluoride concentrations, respectively. The brushings had 7.14g and 14.28g of toothpaste, both for 50mL of deionized water. The surface roughness was reevaluated and data were analyzed by two-way ANOVA and Tukey?s test for the effect of brushing and toothpastes. Results: At the beginning, no significant difference (p=0.09) of roughness was noted among the experimental groups (Prevident, Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brazil): 0.160±0.019; Colgate Total 12 (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brazil): 0.159±0.030; Tandy (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brazil): 0.157±0.019) but roughness decreased after the 1st (p<0.05) (0.094±0.010) and 2nd (0.089± 0.012) brushings (p<0.05) with Prevident 5000 (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brazil), with no significant difference between the 1st and 2nd brushings (p=0.16). Discs brushed with Colgate Total 12 (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brazil) presented surface roughness similar (p=0.090) at the beginning and after the 1st brushing (0.133±0.029), and between the 1st and 2nd (0.113±0009) brushings (p=0.402); roughness after the 2nd brushing was statistically greater than at the beginning (p<0.05). Tandy (Colgate- Palmolive Ind. e Com. Ltda., São Paulo, Brazil) toothpaste caused a surface roughness significantly lower (p<0.05) after the 2nd brushing (0.113±0.010), compared to the 1st (0.147±0.020) and the starting point, which were statistically similar (p=0.090). Conclusion: The results suggest that brushing using toothpastes with fluoride causes a decrease in the surface roughness of cp Ti, mainly when greater fluoride concentrations are present.


Objetivo: Avaliar o efeito da escovação com dentifrícios contendo diferentes concentrações de flúor na superfície do titânio comercialmente puro (Ti cp). Métodos: Discos (13x4mm) de Ti cp, embutidos em anéis de PVC e polidos metalograficamente, tiveram a rugosidade superficial avaliada. A simulação da escovação (50400 ciclos) teve velocidade de 80mm/s, curso de 10mm, com 240 ciclos/min. Foram testados três dentifrícios: Prevident 5000, (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brasil); Colgate Total 12 (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brasil) e Tandy (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brasil), com 5000, 1300 e 500ppm de flúor, respectivamente. As escovações tiveram 7,14g e 14,28g de dentifrício, ambas para 50ml de água deionizada. A rugosidade superficial foi reavaliada e os dados analisados por ANOVA - dois fatores e teste de Tukey quanto ao efeito da escovação e dos dentifrícios. Resultados: Inicialmente não houve diferença significante (p=0,09) na rugosidade dos grupos experimentais Prevident, (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brasil): 0,160±0,019; Colgate Total 12 (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brasil): 0,159±0,030; Tandy (Colgate- Palmolive Ind. e Com. Ltda., São Paulo, Brasil): 0,157±0,019), mas houve diminuição da rugosidade após a 1ª (0,094±0,010) (p<0,05) e 2ª (0,089±0,012) escovações (p<0,05) com Prevident 5000 (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brasil), sem diferença significativa entre as demais (p=0,16). Discos escovados com Colgate Total 12 (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brasil) apresentaram rugosidade semelhante inicialmente (p=0,090) e após a 1ª escovação (0,133± 0,029), e entre a 1ª e a 2ª escovações (0,113±0,009) (p=0,402); a rugosidade após a 2ª escovação foi significativamente maior que a inicial (p<0,05). O dentifrício Tandy (Colgate-Palmolive Ind. e Com. Ltda., São Paulo, Brasil) causou rugosidade superficial significativamente menor (p<0,05) após a 2ª escovação (0,113±0,010), comparada à 1ª (0,147±0,020) e a inicial, que foram semelhantes (p=0,090). Conclusão: Os resultados sugerem que a escovação com dentifrícios fluoretados diminui a rugosidade superficial do Ti cp, mais significativamente quanto maiores as concentrações de flúor presentes.


Subject(s)
Dentifrices , Toothbrushing , Fluorine , Titanium
6.
Braz. dent. j ; 23(5): 496-501, Sept.-Oct. 2012. ilus, graf, mapas, tab
Article in English | LILACS | ID: lil-660350

ABSTRACT

The effects of fluoride, which is present in different oral hygiene products, deserve more investigation because little is known about their impact on the surface of titanium, which is largely used in Implantology. This study evaluated the surface of commercially pure titanium (cpTi) after exposure to different concentrations of sodium fluoride (NaF). The hypothesis tested in this study was that different concentrations of NaF applied at different time intervals can affect the titanium surface in different ways. The treatments resulted in the following groups: GA (control): immersion in distilled water; GB: immersion in 0.05% NaF for 3 min daily; GC: immersion in 0.2% NaF for 3 min daily; GD: immersion in 0.05% NaF for 3 min every 2 weeks; and GE: immersion in 0.2% NaF for 3 min every 2 weeks. The experiment lasted 60 days. Roughness was measured initially and every 15 days subsequently up to 60 days. After 60 days, corrosion analysis and anodic polarization were done. The samples were examined by scanning electron microscopy (SEM). The roughness data were analyzed by ANOVA and there was no significant difference among groups and among time intervals. The corrosion data (i corr) were analyzed by the Mann-Whitney test, and significant differences were found between GA and GC, GB and GC, GC and GD, GC and GE. SEM micrographs showed that the titanium surface exposed to NaF presented corrosion that varied with the different concentrations. This study suggests that the use of 0.05% NaF solution on cpTi is safe, whereas the 0.2% NaF solution should be carefully evaluated with regard to its daily use.


Os efeitos do fluoreto, o qual está presente em diferentes produtos de higiene oral, necessita de maiores investigações, pois pouco se sabe sobre seus efeitos na superfície do titânio, o qual possui amplo uso na implantodontia. Este estudo objetivou avaliar a superfície do titânio comercialmente puro (cpTi) após exposição a diferentes concentrações de fluoreto de sódio (NaF). A hipótese testada neste estudo foi que diferentes concentrações de NaF aplicadas em diferentes intervalos de tempo seriam capazes de afetar diferentemente a superfície do titânio. Os tratamentos realizados foram: GA (controle): imersão em água destilada; GB: imersão diária por 3 min em NaF a 0,05%; GC: imersão diária por 3 min em NaF a 0,2%; GD: imersão quinzenal por 3 min em NaF a 0,05%; e GE: imersão quinzenal por 3 min em NaF a 0,2%. O tempo do experimento foi de 60 dias. A análise da rugosidade foi efetuada inicialmente e a cada 15 dias. Após 60 dias foi realizada análise de corrosão e polarização anódica. As amostras foram analisadas em MEV. Os dados de rugosidade foram analisados por ANOVA e não houve diferença estatisticamente significante entre grupos e entre tempos. Os dados de corrosão (i corr) foram analisados pelo teste de Mann-Whitney e foram encontradas diferenças significantes entre GA e GC, GC e GB, GC e GD, GC e GE. A MEV evidenciou que a superfície do titânio exposto ao NaF apresentou corrosão variando de acordo com a concentração. Com base nos dados encontrados conclui-se que o uso de solução NaF a 0,05% em cpTi é seguro, enquanto a solução NaF 0,2% para uso diário deve ser cuidadosamente avaliada.


Subject(s)
Corrosion , Mouthwashes/chemistry , Sodium Fluoride/chemistry , Titanium/chemistry , Analysis of Variance , Electrochemical Techniques , Microscopy, Electron, Scanning , Surface Properties
7.
Braz. dent. j ; 23(2): 141-148, Mar.-Apr. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-626302

ABSTRACT

The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the general alloy composition. Regarding the alloys containing nickel, the Ni-Cr and Ni-Cr-Ti alloys released 0.62 mg/L of Ni on average, while the Co-Cr dental alloy released ions between 0.01 and 0.03 mg/L of Co and Cr, respectively.The open-circuit potential stabilized at a higher level with lower deviation (standard deviation: Ni-Cr-6Ti = 32 mV/SCE and Co-Cr = 54 mV/SCE). The potenciodynamic curves of the dental alloys showed that the Ni-based dental alloy with >70 wt% of Ni had a similar curve and the Co-Cr dental alloy showed a low current density and hence a high resistance to corrosion compared with the Ni-based dental alloys. Some changes in microstructure were observed and this fact influenced the corrosion behavior for the alloys. The lower corrosion resistance also led to greater release of nickel ions to the medium. The quantity of Co ions released from the Co-Cr-Mo alloy was relatively small in the solutions. In addition, the quantity of Cr ions released into the artificial saliva from the Co-Cr alloy was lower than Cr release from the Ni-based dental alloys.


O objetivo deste estudo foi determinar o efeito do ambiente bucal na corrosão de diferentes ligas odontológicas, utilizando métodos eletroquímicos. Os índices de corrosão foram obtidos por meio das curvas de corrente-potencial e impedância eletroquímica (EIS). O efeito de saliva artificial na corrosão de ligas odontológicas foi dependente da composição. A dissolução dos íons ocorreu em todas as amostras e os resultados foram dependentes da composição da liga. Algumas mudanças na microestrutura foram observadas durante o estudo e influenciou o comportamento corrosivo das ligas investigadas. As ligas de Ni-Cr e Ni-Cr-Ti libertaram quantidade de 0,62 mg/L de íons Ni enquanto a liga de Co-Cr liberou entre 0,01 e 0,03 mg/L. As curvas potenciodinâmicas das ligas odontológicas mostraram que as ligas a base >70 wt% de Ni obtiveram curvas similares e a liga de Co-Cr apresentou a menor densidade de corrente e em consequência uma resistência alta a corrosão quando comparada as ligas à base de Ni. A baixa resistência à corrosão também levou a maior libertação de íons de níquel para o meio e a quantidade de Co liberado pela liga de Co-Cr-Mo foi relativamente pequena nas soluções. As quantidades de Cr liberada na saliva artificial pela liga de Co-Cr foi menor que a libertação de Cr pela liga à base de Ni.


Subject(s)
Corrosion , Dental Alloys/chemistry , Saliva, Artificial/chemistry , Dielectric Spectroscopy , Electrochemistry , Ions , Potentiometry , Surface Properties
8.
J. appl. oral sci ; 19(4): 301-305, July-Aug. 2011. ilus
Article in English | LILACS | ID: lil-599753

ABSTRACT

Titanium reacts strongly with elements, mainly oxygen at high temperature. The high temperature of titanium laser welding modifies the surface, and may interfere on the metal-ceramic tensile bond strength. OBJECTIVE: The influence of laser welding on the titanium-ceramic bonding has not yet been established. The purpose of this in vitro study was to analyze the influence of laser welding applied to commercially pure titanium (CpTi) substructure on the bond strength of commercial ceramic. The influence of airborne particle abrasion (Al2O3) conditions was also studied. MATERIAL AND METHODS: Forty CpTi cylindrical rods (3 mm x 60 mm) were cast and divided into 2 groups: with laser welding (L) and without laser welding (WL). Each group was divided in 4 subgroups, according to the size of the particles used in airborne particle abrasion: A - Al2O3 (250 µm); B - Al2O3 (180 µm); C - Al2O3 (110 µm); D - Al2O3 (50 µm). Ceramic rings were fused around the CpTi rods. Specimens were invested and their tensile strength was measured at fracture with a universal testing machine at a crosshead speed of 2.0 mm/min and 200 kgf load cell. Statistical analysis was carried out with analysis of variance and compared using the independent t test (p<0.05). RESULTS: Significant differences were found among all subgroups (p<0.05). The highest and the lowest bond strength means were recorded in subgroups WLC (52.62 MPa) and LD (24.02 MPa), respectively. CONCLUSION: Airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Mechanical retention decreased in the laser-welded specimens, i.e. the metal-ceramic tensile bond strength was lower.


Subject(s)
Air Abrasion, Dental/methods , Ceramics/chemistry , Dental Bonding/methods , Dental Soldering/methods , Lasers , Titanium/chemistry , Analysis of Variance , Materials Testing , Microscopy, Electron, Scanning , Metal Ceramic Alloys/chemistry , Particle Size , Surface Properties , Tensile Strength
9.
Braz. dent. j ; 22(1): 51-55, 2011. ilus, tab
Article in English | LILACS | ID: lil-582402

ABSTRACT

This study evaluated the loss of the torque applied after use of new screws and after successive tightening. Four infrastructures (IE), using UCLA castable abutment type, were cast in cobalt-chromium alloy and new abutment screws (G1) were used in a first moment. Subsequently, the same abutment screws were used a second time (G2) and more than two times (G3). The values of the torques applied and detorques were measured with a digital torque wrench to obtain the values of initial tightening loss ( percent). Data were analyzed by ANOVA and Tukey's test (?=0.05). Significant differences were observed between the G1 (50.71 percent ± 11.36) and G2 (24.01 percent ± 3.33) (p=0.000) and between G1 (50.71 percent ± 11.36) and G3 (25.60 percent ± 4.64) (p=0.000). There was no significant difference between G2 and G3 (p=0.774). Within the limitations of the study, it may be concluded that the percentage of the initial torque loss is lower when screws that already suffered the application of an initial torque were used, remaining stable after application of successive torques.


O objetivo deste estudo foi avaliar a perda do torque inicial, quando usados novos parafusos de pilares e após sucessivos apertos. Quatro infra-estruturas (IE), utilizando pilares calcináveis tipo UCLA, foram fundidas em liga de cobalto-cromo, onde novos parafusos de pilares foram utilizados (G1) em um primeiro momento. Posteriormente os mesmos parafusos de pilares foram utilizados em um segundo momento (G2), e depois por mais duas vezes (G3). Os valores de torque e detorque aplicados foram mensurados a partir de um torquímetro digital para obtenção dos valores de perda do torque inicial ( por cento). Os dados foram coletados e submetidos à análise de variância e teste de Tukey (p<0,05). Foram observadas diferenças estatisticamente significantes entre os grupos G1 (50,71 por cento ± 11,36) and G2 (24,01 por cento ± 3,33) (p=0,000) and the groups G1 (50,71 por cento ± 11,36) and G3 (25,60 por cento ± 4,64) (p=0,000). Os maiores valores foram encontrados para o grupo G1. Não houve diferença estaticamente significante entre os grupos G2 e G3 (p=0,774). Dentro das limitações deste estudo, pôde-se observar que a porcentagem de perda de torque inicial foi menor quando os parafusos já haviam sofrido a aplicação do primeiro torque, se mantendo estáveis após os demais torques.


Subject(s)
Humans , Dental Abutments , Dental Implants , Dental Restoration Failure , Dental Prosthesis Retention/instrumentation , Chromium Alloys , Cobalt , Models, Dental , Dental Stress Analysis , Equipment Reuse , Mandible , Torque
10.
J. appl. oral sci ; 18(5): 487-492, Sept.-Oct. 2010. graf
Article in English | LILACS | ID: lil-564183

ABSTRACT

The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.


Subject(s)
Chromium Alloys/chemistry , Dental Casting Technique , Denture Retention , Titanium/chemistry , Dental Casting Investment , Dental Clasps , Denture, Partial, Removable , Materials Testing , Porosity , Pressure , Surface Properties , Time Factors , Vacuum
11.
Braz. j. oral sci ; 9(3): 362-365, July-Sept. 2010. ilus, tab
Article in English | LILACS, BBO | ID: lil-578056

ABSTRACT

Aim: The objective of this study was to evaluate the bond strength of four dental ceramics to commercially pure titanium. Methods: To measure the resistance of metal-ceramic bonding,ceramic rings (Noritake Ti22®, Triceran®, IPS®, Noritake EX-3®) were made around metal rodsfused to commercially pure titanium. The area of metal-ceramic union was measured and, after mounting in type III plaster, the rings were subjected to a shearing force in a universal testing machine at a cross head speed of 2 mm/s until failure occurred. The metal-ceramic shear bond resistance was calculated in MPa. Results: The shear bond strength means for the ceramics Triceram and Noritake Ti22 (42.50 MPa and 61 MPa, respectively) were higher than the minimum value required by the DIN 13927 standard (25 MPa). The ceramics IPS and NoritakeEX3, although not specifically formulated for titanium, also had shear bond strength means above the ISO-recommended value (38.47 MPa and 29.04 MPa, respectively); however, there cracks in some specimens after burning and detachment of the ceramic from the metal. Conclusions:The ceramic Noritake Ti22 should be indicated for the commercially pure titanium casting due to its higher mean bond resistance compared to other ceramics utilized.


Subject(s)
Ceramics/chemistry , Dental Bonding/methods , Shear Strength , Titanium/chemistry , Analysis of Variance , Hot Temperature , Materials Testing , Microscopy, Electron, Scanning , Surface Properties
12.
ROBRAC ; 18(47)jan. 2010. tab
Article in Portuguese | LILACS | ID: lil-558295

ABSTRACT

O uso do titânio comercialmente puro (Ti cp) tem aumentado na confecção de estruturas metálicas de próteses. Assim, o objetivo deste trabalho foi avaliar in vitro a resistência à abrasão do Ti cp em oposição a diversos materiais restauradores. Foram fundidos corpos-de-prova de forma hemiesféricas (5mm de raio) em titânio cp grau I por arco voltaico em atmosfera inerte de argônio. Como antagonistas foram preparados discos com 20,0mm de diâmetro de: Ti cp; ligas de Co-Cr e Ni-Cr, resina composta TPH e cerâmica Empress-2, todos com rugosidade de 0,75 micrometro. Foram realizados aproximadamente 40000 ciclos (4,4Hz) sob carga constante de 5N. A resistência à abrasão do titânio foi medida pelo desgaste vertical dos corpos-de-prova hemiesféricos em projetor de perfil Nikon. Os dados foram submetidos à ANOVA e teste complementar de Tukey (alfa=0,05). Os resultados (micrometros) encontrados foram: Ti cp X resina (37,75±7,99); Ti cp X cerâmica (73,25±9,96); Ti cp X Co-Cr (77,17±9,95), Ti cp X Ti cp (199,00±86,90) e Ti cp X Ni-Cr (261,50±39,23). Não houve diferença significante (p>0,05) quando os antagonistas foram de resina, cerâmica e liga de Co-Cr. Quando submetido a antagonistas de Ti cp e liga de Ni-Cr os resultados foram estatisticamente significantes (p<0,05), com maior desgaste contra o antagonista de Ni-Cr. É possível concluir que o material a ser utilizado na arcada antagonista deve ser escolhido cuidadosamente quando as próteses forem confeccionadas em Ti cp porque há o risco de desgaste da prótese.


The use of commercially pure titanium (cp Ti) has increased in prosthodontics frameworks. Thus, the aim of the present study was to evaluate in vitro wear resistance of cp Ti opposing several restorative materials. Hemispheres (r=5mm) were cast in cp grade I by arc melting under inert argon atmosphere. As antagonistic samples, disks of 20mm in diameter were prepared in cp Ti, Co-Cr and Ni-Cr alloy, composite resin and Empress-2 ceramic, and roughness was adjusted to 0.75 micrometro. It was performed approximately 40,000 cycles (4.4Hz) using a load of 5N. Wear resistance of cp Ti was measured as height loss of hemispherical samples in a Nikon profile projector. The data were submitted to ANOVA and post-hoc Tukey test (alfa=0.05). The results (micrometros) were: cp Ti X composite resin (37.75±7.99); cp Ti X ceramic (73.25±9.96); cp Ti X Co-Cr (77.17±9.95), cp Ti X cp Ti (199.00±86.90) and cp Ti X Ni-Cr (261.50±39.23). No significant difference was noted (p>0.05) when antagonistic were composite resin, ceramic or Co-Cr alloy. When cp Ti opposed to cp Ti and Ni-Cr alloy, the results were statistically significant (p<0.05), presenting greater wear when Ni-Cr alloy was used as antagonist. It is possible to conclude that the material used as antagonist should be chosen carefully when titanium frameworks are used because there is a risk of wear of prostheses.

13.
Braz. dent. j ; 21(6): 515-519, 2010. tab
Article in English | LILACS | ID: lil-572297

ABSTRACT

This study compared vertical and passive fit of one-piece cast frameworks made with 3 different materials: commercially pure titanium (CP Ti - G1), cobalt-chromium alloy (Co-Cr - G2) and nickel-chromium-titanium alloy (Ni-Cr-Ti - G3). Fifteen frameworks were obtained simulating bars for fixed prosthesis in a model with 5 implants. The passive and vertical fit of the framework interface was measured using an optical microscope at ×30 magnification. Data were statistically analyzed by ANOVA and LSD tests (α=0.05). Mean and standard deviation values for passive fit and vertical fit were, respectively: G1 [472.49 (109.88) µm and 29.9 (13.24) µm], G2 [584.84 (120.20) µm and 27.05 (10.30) µm], and G3 [462.70 (179.18) µm and 24.95 (11.14) µm]. For vertical fit, there were no significant differences among G1, G2 and G3 (p=0.285). There were no significant differences for passive fit between G1 and G3 (p=0.844), but both differed significantly from G2 (p=0.028 and p=0.035, respectively), which showed the highest misfit values. It may be concluded that the vertical fit of frameworks was not affected by the tested materials, and that one-piece cast frameworks resulted in inadequate passive fit. The Co-Cr alloy presented the worst values for passive fit.


Este estudo tem como objetivo comparar o ajuste vertical e a passividade de infraestruturas em monobloco confeccionadas em 3 diferentes materiais: titânio comercialmente puro (Ti cp - G1), cobalto-cromo (Co-Cr - G2) e níquel-cromo-titânio (Ni-Cr-Ti - G3). Quinze infraestruturas foram obtidas simulando barras para próteses fixas em um modelo com 5 implantes. O ajuste vertical e a passividade da interface da infraestrutura foram medidos usando um microscópio óptico (30×). Os dados foram analisados estatisticamente por meio da ANOVA e teste LSD (α=0,05). A média dos valores e o desvio-padrão da passividade e do ajuste vertical estão apresentados respectivamente: Ti cp [472,49 (109,88) μm e 29,9 (13,24) μm], Co-Cr [584,84 (120,20) μm e 27,05 (10,30) μm], Ni-Cr-Ti [462,70 (179,18) μm e 24,95 (11,14) μm]. Para o desajuste vertical, não houve diferença significante entre o Ti cp e as ligas Co-Cr e Ni-Cr-Ti (p=0,285). Para passividade, não houve diferença significante entre Ti cp e Ni-Cr-Ti (p=0,844), mas ambos foram estatisticamente diferentes do Co-Cr (p=0,028 e p=0,035, respectivamente), o qual apresentou os piores resultados. Pode-se concluir que os materiais utilizados para confecção das infraestruturas não influenciaram o ajuste vertical e que infraestruturas fundidas em monobloco resultaram em inadequados ajustes passivos. A liga de Co-Cr apresentou os piores resultados para a passividade.


Subject(s)
Chromium Alloys , Dental Prosthesis Design/adverse effects , Dental Prosthesis, Implant-Supported/adverse effects , Titanium , Analysis of Variance , Cobalt , Dental Abutments , Dental Casting Technique , Dental Implants , Models, Dental , Endpoint Determination , Nickel , Prosthesis Fitting
14.
J. appl. oral sci ; 17(5): 421-426, Sept.-Oct. 2009. ilus, graf
Article in English | LILACS | ID: lil-531390

ABSTRACT

Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. OBJECTIVE: The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system. MATERIAL AND METHODS: Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure. Discs were immersed in artificial saliva and subjected to different temperatures: 37ºC and thermocycling (37ºC/5ºC/37ºC/55ºC/37ºC). After thermocycling, extracts were put in a subconfluent culture during 6 h, and the number of cells and their viability were used to evaluate cytotoxicity in these temperatures. For each alloy, data from temperature conditions were compared by Student's t-test (α=0.05). RESULTS: The cytotoxicity tests with alloy/metal extracts showed that Ni-Cr, Co-Cr-Mo, Ti-6Al-4V and cp Ti extracts (p>0.05) did not affect cell number or cell viability, while Ni-Cr-Ti (p<0.05) extract decreased cell number and viability when the alloy was subjected to thermocycling. CONCLUSION: Within the limitations of the present study, the Ni-Cr-Ti alloy had cell number and viability decreased when subjected to temperature variation, while the other alloys/metal extracts did not show these results.


Subject(s)
Humans , Dental Alloys/toxicity , Dental Casting Investment/toxicity , Dental Materials/toxicity , Titanium/toxicity , Alloys/chemistry , Alloys/toxicity , Aluminum Oxide/chemistry , Biocompatible Materials/chemistry , Biocompatible Materials/toxicity , Cell Count , Cell Line, Tumor , Carbon Compounds, Inorganic/chemistry , Cell Survival/drug effects , Chromium Alloys/chemistry , Chromium Alloys/toxicity , Dental Casting Technique , Dental Etching , Dental Alloys/chemistry , Dental Casting Investment/chemistry , Dental Materials/chemistry , Dental Polishing/methods , Diamond/chemistry , Materials Testing , Saliva, Artificial/chemistry , Silicon Compounds/chemistry , Silicon Dioxide/chemistry , Temperature , Titanium/chemistry
15.
J. appl. oral sci ; 17(5): 451-456, Sept.-Oct. 2009. ilus, graf
Article in English | LILACS | ID: lil-531396

ABSTRACT

One of the most important properties of artificial teeth is the abrasion wear resistance, which is determinant in the maintenance of the rehabilitation's occlusal pattern. OBJECTIVES: This in vitro study aims to evaluate the abrasion wear resistance of 7 brands of artificial teeth opposed to two types of antagonists. MATERIAL AND METHODS: Seven groups were prepared with 12 specimens each (BIOLUX & BL, TRILUX & TR, BLUE DENT & BD, BIOCLER & BC, POSTARIS & PO, ORTHOSIT & OR, GNATHOSTAR & GN), opposed to metallic (M & nickel-chromium alloy), and to composite antagonists (C & Solidex indirect composite). A mechanical loading device was used (240 cycles/min, 4 Hz speed, 10 mm antagonist course). Initial and final contours of each specimen were registered with aid of a profile projector (20x magnification). The linear difference between the two profiles was measured and the registered values were subjected to ANOVA and Tukey's test. RESULTS: Regarding the antagonists, only OR (M = 10.45 ± 1.42 µm and C = 2.77 ± 0.69 µm) and BC (M = 6.70 ± 1.37 µm and C = 4.48 ± 0.80 µm) presented statistically significant differences (p < 0.05). Best results were obtained with PO (C = 2.33 ± 0.91 µm and M = 1.78 ± 0.42 µm), followed by BL (C = 3.70 ± 1.32 µm and M = 3.70 ± 0.61 µm), statistically similar for both antagonists (p>0.05). Greater result variance was obtained with OR, which presented the worse results opposed to Ni-Cr (10.45 ± 1.42 µm), and results similar to the best ones against composite (2.77 ± 0.69 µm). CONCLUSIONS: Within the limitations of this study, it may be concluded that the antagonist material is a factor of major importance to be considered in the choice of the artificial teeth to be used in the prosthesis.


Subject(s)
Humans , Composite Resins/chemistry , Dental Restoration Wear , Dental Alloys/chemistry , Dental Materials/chemistry , Tooth, Artificial , Acrylic Resins/chemistry , Chromium Alloys/chemistry , Materials Testing , Methacrylates/chemistry , Polymethyl Methacrylate/chemistry , Polyurethanes/chemistry , Stress, Mechanical , Surface Properties
16.
Braz. j. oral sci ; 8(3): 124-127, July-Sept. 2009. ilus, graf
Article in English | LILACS, BBO | ID: lil-563318

ABSTRACT

Aim: The purpose of this study was to evaluate the adaptation of inlay restorations cast in commercially pure titanium (cp Ti) after inclusion of the wax patterns in either a phosphate-bonded investment (Rematitan Plus®) or a silicon oxide-based investment (Termocast®). Methods: The wax patterns were prepared over an inlay-type mold. After waxing, 5 measurements of the marginal adaptation were made on the mesial and distal faces. Five wax patterns were included in each type of investment under vacuum. The cast specimens were repositioned in the mold and other 5 measurements of the adaptation were made based on the same initial testing conditions. Data were analyzed statistically by two-way ANOVA and Duncan’s post-hoc (P<0.01) using the SPSS statistical software package version 12.0 (SPSS, Chicago, IL, USA). Results: The mean marginal discrepancies of the MOD inlays were higher in the Termocast® Group. Termocast® presented significantly greater marginal discrepancy than Rematitan Plus®. Due to the great permeability of the investment refractory material, internal porosity was extremely rare in Rematitan Plus® and more common in Termocast®. Conclusion: It may be concluded that Termocast® investment should not be indicated for cp Ti casting due to poor adaptation and porosity on the casting surface.


Subject(s)
Dental Marginal Adaptation , Inlays/methods , Dental Casting Investment/chemistry , Materials Testing , Porosity , Titanium/chemistry
17.
Braz. dent. j ; 20(3): 201-204, 2009. tab
Article in English | LILACS | ID: lil-526422

ABSTRACT

This study evaluated the effects of fluoride-containing solutions on the surface of commercially pure titanium (CP Ti) obtained by casting. CP Ti specimens were fabricated and randomly assigned to 5 groups (n=10): group 1: stored in distilled water at 37 ± 1ºC; group 2: stored in distilled water at 37 ± 1ºC and daily immersed in 0.05 percent NaF for 3 min; group 3: stored in distilled water at 37 ± 1ºC and daily immersed in 0.2 percent NaF for 3 min; group 4: stored in distilled water at 37 ± 1ºC; and immersed in 0.05 percent NaF every 15 days for 3 min; and group 5: stored in distilled water at 37 ± 1ºC and immersed in 0.2 percent NaF every 15 days for 3 min. Surface roughness was measured with a profilometer immediately after metallographic polishing of the specimens (T0) and at 15-day intervals until completing 60 days of experiment (T15, T30, T45, T60). Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). There was no statistically significant difference (p>0.05) in surface roughness among the solutions. In conclusion, fluoride-containing solutions (pH 7.0) used as mouthwashes do not damage the surface of cast CP Ti and can be used by patients with titanium-based restorations.


Este estudo avaliou o efeito de soluções para enxaguatório bucal contendo fluoreto sobre a superfície do titânio comercialmente puro (cp Ti) após fundição odontológica. As amostras (n=50) foram divididas igualmente: grupo A - armazenadas em água destilada a 37 ± 1ºC, grupo B - armazenadas em água destilada a 37 ± 1ºC e imersão diária em NaF a 0,05 por cento durante 3 min, grupo C - armazenadas em água destilada a 37 ± 1ºC e imersão diária em NaF a 0,2 por cento durante 3 min, grupo D - armazenadas em água destilada a 37 ± 1ºC e imersão em NaF a 0,05 por cento a cada 15 dias por 3 min e grupo E - armazenadas em água destilada a 37 ± 1ºC e imersão em NaF a 0,2 por cento a cada 15 dias durante 3 min. A rugosidade superficial foi medida logo após o polimento metalográfico das amostras (T0) e cada 15 dias de experiência até serem alcançados 60 dias (T15, T30, T45, T60). Os dados foram analisados usando ANOVA (α=0,05) e as diferenças não foram estatisticamente significantes (p>0,05) entre as diferentes soluções. Conclui-se que soluções contendo fluoreto (pH 7,0) não danificam a superfície do Ti cp e podem ser usadas como soluções para bochecho usadas por pacientes que possuem restaurações à base de titânio.


Subject(s)
Cariostatic Agents/chemistry , Sodium Fluoride/chemistry , Titanium/chemistry , Analysis of Variance , Corrosion , Dental Materials/chemistry , Statistics, Nonparametric , Surface Properties
18.
Braz. dent. j ; 20(5): 403-409, 2009. tab, ilus
Article in English | LILACS | ID: lil-537547

ABSTRACT

The aim of this study was to analyze the shear bond strength between commercially pure titanium, with and without laser welding, after airbone-particle abrasion (Al2O3) and 2 indirect composites. Sixty-four specimens were cast and divided into 2 groups with and without laser welding. Each group was divided in 4 subgroups, related to Al2O3 grain size: A - 250 µm; B - 180 µm; C- 110 µm; and D - 50 µm. Composite rings were formed around the rods and light polymerized using UniXS unit. Specimens were invested and their shear bond strength at failure was measured with a universal testing machine at a crosshead speed of 2.0 mm/min. Statistical analysis was carried out with ANOVA and Tukey's test (á=0.05). The highest bond strength means were recorded in 250 µm group without laser welding. The lowest shear bond strength means were recorded in 50 µm group with laser welding. Statistically significant differences (p<0.05) were found between all groups. In conclusion, airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Shear bond strength decreased in the laser welded specimens.


O objetivo deste estudo foi analisar a força de união entre o titânio comercialmente puro com solda e sem solda modificado por partículas de óxido de alumínio (Al2O3) e duas resinas indiretas. Um total de 64 espécimes foram fundidas e divididas em dois grupos sem solda e com solda a laser. Cada grupo foi novamente divididos em 4 subgrupos, de acordo com o tamanho de partículas de óxido de alumínio utilizado: A - Al2O3 (250 µm); B - Al2O3 (180 µm); C- Al2O3 (110 µm); D - Al2O3 (50 µm). Anéis de resina foram polimerizados ao redor das hastes de titânio no equipamento UniXS. Os espécimes foram embutidos em gesso e a força de união foi mensurada com auxílio da máquina de ensaios universais. ANOVA e teste de Tukey (p<0,05) foram utilizados para análise estatística. Os maiores valores de força de união foram registrados no grupo de 250 µm sem solda a laser. Os menores valores foram registrados para o grupo de 50 µm com solda a laser. Alterações estatisticamente significantes foram observadas entre todos os grupos (p<0,05). As forças de união diminuíram significantemente com a diminuição dos tamanhos das partículas de óxido de alumínio. A força de união diminuiu nas amostras que receberam a solda a laser.


Subject(s)
Composite Resins , Dental Alloys , Dental Soldering/methods , Light-Curing of Dental Adhesives , Titanium , Air Abrasion, Dental , Analysis of Variance , Dental Stress Analysis , Lasers , Materials Testing , Particle Size , Shear Strength , Statistics, Nonparametric , Welding/methods
19.
Braz. dent. j ; 19(2): 134-138, 2008. ilus, tab
Article in English | LILACS | ID: lil-484950

ABSTRACT

This study evaluated the effect of chemical and mechanical surface treatments for cast metal alloys on the bond strength of an indirect composite resin (Artglass) to commercially pure titanium (cpTi). Thirty cylindrical metal rods (3 mm diameter x 60 mm long) were cast in grade-1 cpTi and randomly assigned to 6 groups (n=5) according to the received surface treatment: sandblasting; chemical treatment; mechanical treatment - 0.4 mm beads; mechanical treatment - 0.6 mm beads; chemical/mechanical treatment - 0.4 mm; and chemical/mechanical treatment - 0.6 mm beads. Artglass rings (6.0 mm diameter x 2.0 mm thick) were light cured around the cpTi rods, according manufacturer's specifications. The specimens were invested in hard gypsum and their bond strength (in MPa) to the rods was measured at fracture with a universal testing machine at a crosshead speed of 2.0 mm/min and 500 kgf load cell. Data were analyzed statistically by one-way ANOVA and Tukey test (a=5 percent). The surface treatments differed significantly from each other (p<0.05) regarding the recorded bond strengths. Chemical retention and sandblasting showed statistically similar results to each other (p=0.139) and both had significantly lower bond strengths (p<0.05) than the other treatments. In conclusion, mechanical retention, either associated or not to chemical treatment, provided higher bond strength of the indirect composite resin to cpTi.


Este estudo avaliou o efeito de tratamentos de superfície químico e mecânico para ligas metálicas fundidas sobre a resistência de união de uma resina composta indireta (Artglass) ao titânio comercialmente puro (Ti cp). Trinta varetas cilíndricas metálicas (3 mm diâmetro x 60 mm comprimento) foram fundidas em Ti cp grau 1 e igualmente divididas em grupos de acordo com os seguintes tratamentos de superfície: jateamento, químico, mecânico com esferas de 0,4 mm, mecânico com esferas de 0,6 mm, químico/mecânico com esferas de 0,4 mm e químico/mecânico com esferas de 0,6 mm. Anéis de Artglass (6 mm diâmetro X 2 mm espessura) foram fotopolimerizados ao redor das varetas, de acordo com as recomendações do fabricante. Os corpos-de-prova foram embutidos em gesso-pedra e a resistência de união (MPa) foi medida em uma máquina universal de ensaios com velocidade de 2,0 mm/min e célula de carga de 500 kgf. Os dados foram analisados estatisticamente por ANOVA a um critério e teste de Tukey (a=5 por cento). Houve diferença estatisticamente significante (p<0,05) entre os tratamentos de superfície quanto à resistência adesiva. Retenção química e jateamento apresentaram resultados estatisticamente semelhantes (p=0,139), e ambos apresentaram menores valores de retenção que os demais tratamentos (p<0,05). Em conclusão, a retenção mecânica, associada ou não a tratamento químico, apresentou melhores resultados de resistência adesiva do compósito indireto ao Ti cp.


Subject(s)
Humans , Composite Resins/chemistry , Self-Curing of Dental Resins/methods , Dental Bonding/methods , Dental Materials/chemistry , Titanium/chemistry , Aluminum Oxide/chemistry , Dental Veneers , Light-Curing of Dental Adhesives/methods , Dental Cements/chemistry , Dental Etching/methods , Materials Testing , Stress, Mechanical , Surface Properties , Silanes/chemistry , Tensile Strength
20.
Braz. dent. j ; 19(4): 358-363, 2008. ilus, tab
Article in English | LILACS | ID: lil-504201

ABSTRACT

This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100 percent) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37 percent) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.


Este trabalho teve como objetivo correlacionar o nível de desajuste vertical pilar/implante a perda do torque aplicado (destorque). Um modelo de trabalho foi obtido a partir de uma matriz metálica com cinco implantes tipo hexágono externo (Titamax, Neodent, Curitiba, Brasil) com plataforma regular (4,1 mm). Sobre esta matriz, quatro infra-estruturas foram enceradas utilizando pilares tipo UCLA e fundidas em monobloco com titânio comercialmente puro (Tritan grau I, Dentaurum, Alemanha). Os desajustes foram analisados com um microscópio óptico comparador (Mytutoyo, Japão) após torque de 20 Ncm. O maior valor de desajuste observado por pilar foi utilizado. O valor do torque de desaperto, avaliado com um torquímetro digital (TQ-680, Instrutherm, Brasil), foi calculado em porcentagem do valor do torque inicial (100 por cento) dado aos parafusos protéticos. O teste de correlação de Pearson (p<0,05), entre os valores de desajuste (29,08 ± 8,78 µm) e as porcentagens da perda de torque (50,71 ± 11,37 por cento), não mostrou correlação estatisticamente significante (p=0,295) entre tais fatores. Dentro das limitações do estudo, pode ser concluído que não necessariamente grandes valores de desajustes verticais implicarão em grades perdas de torque.


Subject(s)
Dental Abutments , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Dental Implantation, Endosseous/adverse effects , Dental Implants/adverse effects , Dental Prosthesis Retention/instrumentation , Models, Dental , Dental Stress Analysis , Prosthesis Fitting , Torque
SELECTION OF CITATIONS
SEARCH DETAIL